PEM(OBC&DCDC two in one)

PEM(OBC&DCDC two in one)
OBC+DCDC

Shut
Consult
Hotline:0513-80767818


Functional Configuration

  • OBC+DCDC


Main Specifications

  • Operating modes: 4 types

  • Mod1(AC to HV):high voltage charging mode

    Input AC 220V/32A, HV output DC500-720V, charging power 6.6kW, efficiency>92%

  • Mod:3(HV to AC):Inverter discharge mode

    Input AC 220V/32A, HV output DC500-720V, high-voltage charging power 5.6kW. Efficiency>92%

  • LV output 9-16V/70A, low-voltage charging power 1kW

  • Mod2(AC to HV&LV):high voltage and low voltage simultaneous charging mode

    HV input DC720, output AC220V/32A, inverter power 6.6kW. Efficiency>92%

  • Mod4(HV to LV): DCDC mode

    HV input DC720, LV output 9-16V/250A, low voltage charging power 3kW. Efficiency>92%